Textured Coatings of America, Inc.
|
1. Product Name
TEXCOTE® XL-70®2. Manufacturer
Textured Coatings of America, Inc.
Sales Office
4101 Ravenswood Road Suite 105A
Ft. Lauderdale, FL 33312-5371
PHONE: (954) 581-0771
Fax: (954) 581-95163. Product Description
BASIC USE & COMPOSITION
TEXCOTE® XL-70® Concrete/Masonry Protective Coating is a high-build, plasticized, vinyl toluene acrylic resin system specially formulated to provide a weatherproof coating over cured or uncured concrete masonry surfaces. The ability to go over damp or high alkaline surfaces is a key feature. This coating is recommended for use over all types of concrete, cement plaster, block, brick and other manufacturer approved surfaces.PACKAGING & COVERAGE
Container sizes - 5, 30 and 55 gal (19, 113 and 209 L). Material coverage rates vary due to surface porosity, texture and application method.COLORS
Product is available in TEXCOTE® standard colors. Contact the manufacturer for special color matching which is available for most colors.FINISHES
LIMITATIONS
- Roller Applied - Smooth, fine texture
- Spray Applied - Smooth, fine, coarse, extra coarse textures
TEXCOTE® Textured Coatings are for use in above grade applications only.Joint sealants used must be compatible with selected TEXCOTE® products. Contact the manufacturer to confirm compatibility.
4. Technical Data
APPLICABLE STANDARDS
American Society for Testing & Materials:PHYSICAL/CHEMICAL PROPERTIES
- ASTM B117-95 - Operating Salt Spray (Fog) Apparatus
- ASTM D968-93 - Abrasion Resistance of Organic Coatings by Falling Abrasive
- ASTM D522-93a - Standard Test Methods for Mandrel Bend Test of Attached Organic Coatings
- ASTM D2243-95 - Freeze-Thaw Resistance of Water-Borne Coatings
- ASTM D4141-95 - Standard Practice for Conducting Accelerated Outdoor Exposure Tests of Coatings
- ASTM E84-96a - Standard Test Method for Surface Burning Characteristics of Building Materials
- ASTM E96-95 - Standard Test Methods for Water Vapor Transmission of Materials
- ASTM E514-90(1996)e - Standard Test Method for Water Penetration and Leakage Through Masonry
TEXCOTE® XL-70® comply with the test, results and ratings indicated in Table 1.TABLE 1 PHYSICAL PROPERTIES OF TEXCOTE® XL-70®
Property & Test TEX•COTE® XL-70 Fed Spec TT-C555B, Type I & II Complies Flame spread, ASTM E84, NFPA (Uniform Building Code) Class A (Class 1) Wind driven rain test, ASTM E514 at 98 mph (158 kph) Pass Water vapor permeability, ASTM E96 >.27 perms (15.5 ng/Pa•s•m) Accelerated weathering, ASTM D4141 10,000 hr Flexibility, ASTM D522 mandrel bend test 1" (25.4 mm) Freeze/thaw resistance, ASTM D2243 375 cycles Salt spray exposure, ASTM Bl17-64, Standard Method 3000 hr Abrasion resistance, ASTM D968 10% erosion at 2,000 L
5. Installation
PREPARATORY WORK
All surfaces must be sound and clean. Surface contaminants such as dust, dirt, mildew, form oils and laitance must be thoroughly removed. Painted surfaces exhibiting loose, flaking, or oxidized paint surfaces must be thoroughly removed by sand blasting, water blasting, electric sanding, or wire brushing as required by the manufacturer. All surfaces must be primed prior to coating substrates.TEXCOTE® XL-70® can be applied over damp, uncured concrete, masonry surfaces. TEXCOTE® XL-70® can be applied without a primer on approved concrete surfaces.
Large cracks, holes or voids must be filled with cement patching compound with Tex-Bond Cement Adhesive. Patching compound finish texture to match existing adjacent finish surfaces. Cracks over 1/16" (1.6 mm) and less than 1/8" (3.2 ram)should be filled with FlexPatch Patching Compound. Interfacing of wall joints must be sealed with a urethane type sealant.
Metals
A detailed technical data sheet on surface preparation, degreasing, and etching is available for all applications on metal surfaces. Consult a local TEXCOTE® representative prior to commencing application on metals.A sample wall is recommended for field approval by the architect, manufacturer's representative, and contractor.
APPLICATION PRECAUTIONS
Apply TEXCOTE® XL-70® only under the following conditions:
- Roof and parapet top caps are installed and sealed against water penetration
- Primer exposed to ultraviolet rays for more than four weeks requires repriming
- Joint sealants have cured minimum 48 hours
- Retaining walls, planter boxes and similar construction are waterproofed on the soil side
- Rain is not imminent and surfaces are not damp or frozen; avoid freezing product
- Surface and ambient air temperature range is 40°F - 100°F (5°C - 38°C]
This product, when still in liquid form, contains petroleum distillate which will cause serious illness or death if swallowed or if large quantities are absorbed into body. Use in well ventilated areas. Use approved respirator in poorly ventilated areas. Keep liquid product away from heat sources and children. If swallowed, do not induce vomiting. Seek medical treatment immediately.
ROLL ON APPLICATION METHODS
Short, medium, or long nap rollers can be used for standard applications, depending on texture desired.With fully loaded roller, apply first coat at approximately
90 - 100 sf/gal (2.2 - 2.5 m2/L).
Allow 24 hour curing. Apply second coat at approximately
90 - 100 sf/gal (2.2 - 2.5 m2/L) to achieve a pinhole free, continuous film. When rolling, apply first with vertical strokes, then cross roll for even film and desired appearance.TABLE 2 RECOMMENDED PRIMERS Substrate Primer Concrete, XL-70® Primer uncured, bare Cement plaster XL-70® Primer Block systems XL-70® Slush Cote Primer 1098D or TEX•COTE® Block Filler Masonry, painted No. 62 Brick (bare) XL-70® Primer MDO plywood No. 62 Galvanized steel Primer No. 101 Aluminum Primer No. 101 Ferrous steel Zinc chromate Copper Primer No. X-100SPRAYED ON APPLICATION METHODS
Provide spray equipment similar to Graco President, 10:1 pump or Graco GM 1030 and Graco 204-000 Spray Gun. A TEXCOTE® spray application manual is available upon request.Installer must comply with the following:
- Application of TEXCOTE® must be at uniform pinhole free continuous film thickness over the entire surface.
- Maintain a wet edge at all times to prevent lap marks. Avoid starting and stopping midway on the wall surface. Continue spraying to a natural break point such as a panel edge, seam or corner.
- For large surface areas, two people spraying simultaneously are recommended to avoid lap marks and spray patterns. To achieve a proper surface, request the assistance of the manufacturer's representative.
- Apply coating at a rate of 30-50 sf/gal (.7 - 1.25 m2/L) depending upon the porosity of the substrate and finish texture desired. A minimum of 15-17 mils (.38 - .43 mm) dry film thickness is required. Consult the manufacturer for standard textures and specific coverage rates for texture to be used and samples.
CLEAN UP
Use mineral spirits for cleaning wet material. Use Methyl Ethyl Ketone (MEK) to remove dry material. Attempt sample in concealed area first.SHELF LIFE
- 12 month shelf life under proper conditions
- Containers must be stored upright and airtight in a dry place.
- Maintain air temperature of 45°F - 100°F (7°C - 38°C)
- Skins formed on surface of material must be removed prior to moving containers or mixing.
6. Availability & Cost
TEXCOTE® products are available from representatives in most cities throughout the United States by contacting the manufacturer.7. Warranty
A limited warranty for purchase cost of material is available from Textured Coatings of America, Inc. for applications complying with the manufacturers recommendations, when requested in advance of the application. Contact the manufacturer for specimen copy of warranty.8. Maintenance
No special maintenance is required. Should TEXCOTE® Textured Coatings become soiled, clean with light water pressure and mild detergent.9. Technical Services
Technical services are available from the manufacturer's facilities or sales representatives throughout the United States. Contact the Sales Office or the following:Textured Coatings of America, Inc.
Western Plant
5950 South Avalon Boulevard
Los Angeles, CA 90003-1384
Phone: (323) 233-3111
Fax: (323) 232-1071
Textured Coatings of America, Inc.
Corporate Headquarters & Eastern Plant
2422 East 15th Street
Panama City, FL 32405-6348
Phone: (850) 769-0347
Toll Free: (800) 454-0340
Fax: (850) 769-833910. Filing Systems
- Architects' First Source for Products
- MANU-SPEC®
- Sweet's Catalog Files
- Additional product information is available from the manufacturer.
TC-XL70-1297