Textured Coatings of America, Inc.

TEX•COTE® Multi-Texture/Color (MT/C)
WALL COATING SYSTEM

1. PRODUCT NAME

TEX•COTE® Multi-Texture/Color (MT/C) Wall Coating System

2. MANUFACTURER

Textured Coatings of America, Inc.
Western Plant

5950 South Avalon Boulevard
Los Angeles, CA 90003-1384
PHONE: (323) 233-3111
Fax: (323) 232-1071

Textured Coatings of America, Inc.
Corporate Headquarters and Eastern Plant

2422 East 15th Street
Panama City, FL 32405-6348
PHONE: (850) 769-0347
Fax: (850) 769-8339
Toll Free: (800) 454-0340

Textured Coatings of America, Inc.
Sales Office

4101 Ravenswood Rd., Ste. 105A
Ft. Lauderdale, FL 33312-5371
PHONE: (954) 581-0771
Fax: (954) 581-9516

3. PRODUCT DESCRIPTION

Basic Use: Pigmented, textured interior/exterior seamless wall finish. For use on a wide range of wall surfaces, such as drywall, concrete, concrete block, brick, stucco, wood, glass, plaster, metal, and plastic. Excellent as a "camouflage" coating over existing blemished surfaces.

Designed for spray application, a variety of textures is possible; fine, medium, or heavy splatter; medium or heavy lace; bark; cypress; and other special textures.

Durable, flexible, odorless, and has rapid drying properties with long term adhesion qualities. Excellent breathability. Fungus and mildew resistant.

An environmentally safe coating system, fully compliant with all existing Volatile Organic Contents (V.O.C.) regulations.

Composition and Materials: Combination of a water-based urethane and 100% acrylic-based terpolymer with elastomeric properties. Coating system consists of a MT/C Base Coat and MT/C Finish Coat over properly primed substrates.

Limitations: Do not apply TEX•COTE® Multi-Texture/Color until the following conditions are satisfied:

Quantities and Colors:
Container Sizes: 1 gallon and 5 gallon pails.
Colors: Range of standard colors; custom colors available.

4. TECHNICAL DATA

TEX•COTE® Multi-Texture/Color (MT/C) Wall Coating System passes Federal Test TTC-555b test criteria and performs well for a variety of other testing procedures (i.e. NFPA, ASTM) as shown on the accompanying table.

PHYSICAL CONSTANTS OF MT/C BASE COAT:

   Latex System                        Urethane Acrylic Based
   Weight Per Gallon                   12.2 lbs. typical
   V.O.C. (GMS/liter minus water)      74.4 typical
   Volume Solids                       55.89%

PHYSICAL CONSTANTS OF MT/C FINISH COAT:

   Latex System                        Acrylic Based
   Weight Per Gallon                   10.0 lbs. typical
   V.O.C. (GMS/liter minus water)      162.5
   Volume Solids                       51.80%

TEST DATA TEX•COTE® Multi-Texture/Color SYSTEM

1. Fire
   ASTM E-84 Class A                   Flame Spread 5
                                       Smoke Developed 5
   NFPA                                Class A
   UBC                                 Class 1

2. Water Vapor Permeability
   ASTM E 96 (Procedure A)             13.35 (Perm. In.)
   ASTM D 1653                         17.40 (Perm. In.)

3. Mildew Fungus Resistance
   ASTM D 3273 (TTP 29)                No Disfigurement
   ASTM G21-90 (without clear glaze)   0 Growth
   ASTM G21-90 (with clear glaze)      0 Growth

4. Stain Resistance
   Modified ANSI A 118.6-85            No Visible Stains
   ASTM 1308-87                        No Visible Staining from mild
                                       acids, chemicals, oils, food

5. Flexibility
   ASTM 522-89 Mandrel                 No Cracking

6. Scrub Resistance
   ASTM 2486-89 (without clear glaze)  Pass 9,000 cycles
   ASTM 2486-89 (with clear glaze)     Pass 11,000 cycles

7. Abrasion Resistance
   ASTM 986                            Pass 1,000 cycles

8. Impact Resistance
   Type D Durometer                    40
ADDITIONAL TEST ON MT/C FINISH COAT:
1. Twin ARC Weatherometer (Hours)      5,000 Hours
2. Federal Test
   TTC-555b                            Passes
3. Wind Driven Rain Test
   (98 MPH/24 Hours)                   Passes

4. Salt Spray Test ASTM B-117-64       300 Hours
5. Alkali Resistance
   GSA Exception #1 to TTC-555b        Passes

5. INSTALLATION

Application Equipment: Suitable spray equipment for the base and finish coats. Base coat, only, may be roller coated. Special texturing utilizes equipment recommended by manufacturer.

Surface Preparation: Remove all surface contaminants, including dust, dirt, mildew, form oils, laitance, and other potential bond breakers. Removal means may include sandblasting, waterblasting, electric sanding, or wire brushing, pursuant to manufacturer's recommendations.

Fill large cracks, holes, or voids with an appropriate patching compound, texturing to match adjacent surface. For cracks between 1/16" - 1/8" in width, cut out and fill with recommended patching compound.

Recommended Primers: Dependent upon substrate and exposure (interior or exterior); refer to chart.

All primers must cure pursuant to manufacturer's instructions under acceptable environmental conditions prior to coating system application.

RECOMMENDED SUBSTRATES/PRIMERS (Interior):

SUBSTRATE                                           PRIMER
Drywall                                 No Primer Required
Concrete                                No Primer Required
Cement Plaster                          No Primer Required
Plastic (except polyethylene or polypropylene)        No Primer Required
Glass                                   No Primer Required
Brick                                   No Primer Required
Concrete Block                      TEX•COTE® Block Filler
Wood/Particle Board                              Primer 62
Ceramic Tile                                     X-100 19C
Glazed Block                      X-100 19C or X-100 Epoxy

RECOMMENDED SUBSTRATES/PRIMERS (Exterior):

SUBSTRATE                                           PRIMER
Concrete (Uncured, Bare)                            XL-70®
Cement Plaster                                      XL-70®
Block System (new)                XL-70® Slush•Cote, 1098D
                           or TEX•COTE® Latex Block Filler
Masonry (Painted)                                   No. 62
Brick (Bare)                                        XL-70®
Cement Fibre Board                                  No. 62
Galvanized Steel*                                  No. 101
Aluminum                                           No. 101
Ferrous Steel                                Zinc Chromate
Copper                                         X-100 Epoxy
* If new refer to TEX•COTE® Reditex data sheet.

6. REPAIR AND MAINTENANCE

Uncured During Application: Scrape off undesirable texture with a broad knife. Smooth down as much as possible. Let dry and re-apply base coat to repaired area. Once base coat has dried, re-apply desired texture.

After Full Cure: If needed, existing texture may be removed using a latex paint stripper. Mask off surrounding areas to be repaired. Apply stripper and allow to soak for 20 minutes. Use a paint scraper to scrape off remover and loosened finish. For stubborn areas, use dry #2 coarse steel wool, sand paper, or a wire brush; and scrub loose. Make necessary repairs to substrate with an appropriate patching compound and materials. Ensure that patched areas are finished so that they are flush with surrounding substrate. Wipe clean with a damp cloth and let dry. Re-apply MT/C base coat to repaired area. Once base has dried, re-apply finish coats in the desired order and texture.

Application:

Base Coat to provide uniform pinhole-free film over entire surface.
Finish Coat applied to desired texture, pursuant to manufacturer's recommendations. Guideline coverage rates as defined in chart. Optional top coats available; consult manufacturer.

  Approximate
Coverage Rate
sq. ft. per gallon
Approximate
Tip Size
Approximate
Air Pressure
MT/C BASE COAT
INTERIOR          
150 - 250    
           EXTERIOR 100 - 200    
MT/C FINISH COAT
SPLATTER TEXTURE
 
 
Fine
Medium
Heavy
per finish
color(coat)
225
175
125
single finish
color (coat)
150
125
75
 
 
2-4 mm
4.6 mm
6mm
 
 
40-55 PSI
25-35 PSI
15-25 PSI
LACE TEXTURE  
Medium
Heavy
 
175
125
 
100
75
 
4-6 mm
6 mm
 
25-35 PSI
15-25 PSI
BARK OR CYPRESS TEXTURE
(requires knock down application)
 
Medium
Heavy
 
175
125
 
100
75
 
4-6 mm
6 mm
 
25-35 PSI
15-25 PSI
Optional Top Coats
MT/C CLEAR GLAZE
250-300    
Sacrificial Graffiti Guard® 200-300    
Permanent Graffiti Gard® IIIs Consult Manufacturer    
Coverage rates may vary due to wall textures and porosity.

AVAILABILITY AND COST

Available nationally through representative network. Call the manufacturer for location of nearest representative.

WARRANTY

Limited 5 years material warranty is available upon request.

MAINTENANCE

None beyond routine cleaning with water and mild detergent.

TECHNICAL SERVICES

Available through sales representatives or directly from manufacturer.

 