TEXCOTE¨ GRAFFITI GARD¨ IIIs Exterior/Interior Graffiti Repellent System (Two Component, Solvent, Aliphatic Urethane System) Finish has excellent chemical, ultra-violet, weather, mar and abrasion resistance.
I. PRODUCT DESCRIPTION
TEXCOTE¨ GRAFFITI GARD¨ IIIs System consists of two basic coatings:
- TYCOTE CLEAR OR PIGMENTED-Base Coat TYCOTE CLEAR acts as a "fill coat" for the substrate and maintains clarity.
(Must create a continuous PINHOLE FREE film).TYCOTE PIGMENTED protects old paint from solvents in the TEXCOTE¨ GRAFFITI GARD¨ IIIs Finish Cote and can match customer's specified color. Will also act as a "Fill coat" for the substrate. (Must create a continuous PINHOLE FREE film).
- TEXCOTE¨ GRAFFITI GARD¨ IIIs - Finish Coating, a two component, solvent, aliphatic urethane system clear finish.
There are also two affiliated products which can be used in conjunction or independent of the GRAFFITI GARD¨ IIIs System. They are:
- TEXCOTE¨ STAIN BLOCKER which is applied over surfaces which already have graffiti to prevent the migration of the existing graffiti into the anti-graffiti coating system, and;
- GRAFFITI GARD¨ IIIs PASTE CLEANER, a cleaning solution to remove graffiti from the surface of the GRAFFITI GARD¨ IIIs System.
TEXCOTE¨ GRAFFITI GARD¨ IIIS is recommended over: CONCRETE GALVANIZED METAL CEMENT FIBRE BOARD TILE CEMENT PLASTER BLOCK SYSTEMS BRICK SYSTEMS OTHER MANUFACTURER APPROVED SURFACES Note: Masonry, including mortar and concrete plaster, must cure a minimum of 28 days prior to applying the TEXCOTE¨ GRAFFITI GARD¨ IIIs Systems. II. APPLICATION/EQUIPMENT:
TYCOTE CLEAR, TYCOTE PIGMENTED, TEXCOTE¨ GRAFFITI GARD¨ IIIs FINISH and GRAFFITI STAIN BLOCKER
SPRAY ON:
Commercial Grade Spray Equipment such as a GRACO EM 590 (formerly EH 333 Model) or comparable equipment.ROLL ON:
Medium Nap Roller for TYCOTE Short Nap Roller for TEXCOTE¨ Stain Blocker
NOTE: Do not overwork the roller when applying TYCOTE Clear, as any excessive cavitation can cause bubbles. Try a test area first. Consult Manufacturer's Representative for specific material applications.III. LIMITATIONS:
- TEXCOTE¨ Graffiti System shall be applied under ideal weather conditions.
- Graffiti marred surfaces may need to be treated with Graffiti Stain Blocker, prior to application of Pigmented TYCOTE.
- Rain is not imminent, surfaces are not damp or frozen.
- Temperature is within 50¡F and rising to 90¡F range.
- Incompatible Form Oils, Concrete Curing Agents, Old Chalking Paints, Laitance, etc., must be removed prior to application.
- Retaining walls, planter boxes, etc. should be waterproofed with a below grade asphalt type sealer on side of wall exposed to back-fill.
- TEXCOTE¨ GRAFFITI GARD¨ IIIs System is for Above Grade use only. Do not use Below Grade.
- TEXCOTE¨ GRAFFITI GARD¨ IIIs Finish shelf life is 6 months at room temperature. TYCOTE Clear & Pigmented, GRAFFITI GARD¨ IIIs Paste Cleaner and Graffiti Stain Blocker shelf life is 12 months at room temperature. Container should be stored upright, sealed airtight to prevent moisture intrusion.
- TEXCOTE¨ GRAFFITI GARD¨ IIIs Finish contains petroleum distillate which, in liquid form can cause serious illness or death if swallowed or if large quantities are absorbed into the body. Use only in well ventilated areas.
- Do not store or use near excessive heat or open flame.
- A respirator such as 1482-G102 (H.S.C. Corporation) or equal should be worn when spraying TEXCOTE¨ GRAFFITI GARD¨ IIIs Finish or TEXCOTE¨ Graffiti Cleaner. (Respirator should comply with OSHA Regulation 29 CFR1910134.)
- Important: Intercoat adhesion of TEXCOTE¨ GRAFFITI GARD¨ IIIs Finish to itself after overnight cure or longer is poor. Additional coats can be applied after previous coat has set to touch (approximately 1-3 hours depending on temperature and film thickness).
IV. TECHNICAL DATA
1. GRAFFITI GARD¨ TYCOTE GRAFFITI GARD¨ TYCOTE
Percent Solids (wt.)
Volume Solids
Viscosity, Kreb Units
(77¡±1¡F)
Base CoatCLEAR
27.0 Typical
24.0 Typical
54±2 Typical
Urethane BasePIGMENTED
70.0 Typical
56.5 Typical
104±2 Typical
Acrylic Base2. GRAFFITI GARD¨ IIIs FINISH (Pan A & B: Mixed 50/50 by Volume)
Percent Solids
Volume Solids
Viscosity, Kreb Units
(77±1¡F) (A+B)
Pot Life40.8 Typical
35.97 Typical
50.0±2 Typical
Up to 3 hours
(Depending on temperature and batch sizes)Cure Time-Room Temperature:
Set to Touch
Tack Free
Hard
Maximum Cure
Resin System
1 - 2 Hours
4 - 5 hours
Overnight
36 Hours to 3 days Depending on Temperature and Humidity
Aliphatic UrethaneSolvent Systems comply with California Air Pollution Control Rule 66 3. TEXCOTE¨ STAIN BLOCKER
A water-based, pigmented acrylic primer designed to help control certain types of graffiti from bleeding through the TYCOTE when the GRAFFITI GARD¨ IIIs is to be applied. To be applied at a rate of 400-500 square feet of wall area (depending upon porosity) between air and wall temperatures of 50¡ to 90¡ F.
Percent Solids 30.5 Typical Viscosity, Kreb Units 70 (minimum) 77±1¡F Wt./Gallon (lbs.) 8.3 TypicalV. SURFACE PREPARATION
All surfaces must be sound and cleaned with a manufacturer's approved detergent, or adequately sandblasted, wire brushed, scraped or suitable alter- native. Such surface contaminants as dust, environ- mental dirt, mildew, form oils and loose substrate shall be thoroughly removed by sandblasting, waterblasting, sanding or wire-brushing as required by the manufacturer.
VI. APPLICATION OF TEXCOTE¨ GRAFFITI GARD¨ IIIs
A sample wall is recommended for field approval by Architect, Manufacturer's Representative and Contractor. Provide a properly prepared, dry surface for the TEXCOTE¨ GRAFFITI GARD¨ IIIs System. (Note: Special surfaces may require a primer).
- Inspect opened container. Remove any skins, mix thoroughly prior to use. DO NOT THIN.
- Application of each system shall be a uniform pinhole free, CONTINUOUS FILM over entire surface.
- To prevent lapmarks, avoid starting and stopping midway on wall surface but continue to a natural breaking point such as a panel edge, seam or corner.
CAUTION:
TYCOTE must cure a minimum of 24 hours prior to application of GRAFFITI GARD¨ IIIs. GRAFFITI GARD¨ IIIs must cure a minimum of 1 hour and a maximum of 4 hours between applying a second coat, additional coats after 4 hour cure could cause an adhesion problem. Graffiti Stain Blocker cannot be used with TYCOTE Clear.
Sq. Ft. Per Dry
Surface/Condition Product Application Gal/Coat Time
NEW SUBSTRATES TY•COTE (Clear) Spray 200 24 Hrs.
Cement Plaster or
Stucco, TY•COTE (Pigmented) Spray-Roll 200 24 Hrs.
Brick, Concrete.
Ensure wall is
cleaned and GRAFFITI GARD¨ IIIs
prepared for a (1st Coat) Spray 350 1 Hr. Min.
typical paint (2nd Coat) Spray Fog Coat 350 4 Hr. Max.
application.
Concrete block - (CMU) requires a minimum of two coats of TY•COTE to
achieve a pinhole free surface. An approved mock-up panel is requested
prior to the job proceeding. When utilizing TY•COTE Clear----spray
and back roll with short nap roller. Do not overwork when rolling.
May cause a foaming action.
Cement Plaster, PRIMER 62 Spray-Roll 250 24 Hrs.
Stucco, Brick,
Concrete or CMU's TY•COTE (Pigmented) Spray-Roll 200 24 Hrs.
GRAFFITI GARD¨ IIIs
(1st Coat) Spray 350 1 Hr. Min.
Power wash & (2nd Coat) Spray Fog Coat 350 4 Hr. Max.
clean all wall areas.
Remove all chalk.
Patch & repair as needed.
OTHER SURFACES Consult TCA for specifications.
CLEANUP TY•COTE CLEAR For wet material use water.
For dry material use denatured
alcohol.
TY•COTE For wet material use water.
PIGMENTED For dry material Methyl-Ethyl
Ketone (MEK), Xylene or Toluene.
TEX•COTE¨ For wet material, use
GRAFFITI GARD¨ IIIs Methyl-Ethyl Ketone.
For dry material, scrape or
wire brush.
TEX•COTE¨ For wet material use soap
STAIN BLOCKER and water. For dry material use
Methyl-Ethyl Ketone (MEK) or Xylene
CAUTION:
TY•COTE must cure a minimum of 24 hours prior to application
of GRAFFITI GARD¨ IIIs. GRAFFITI GARD¨ IIIs must cure a minimum of
1 hour and a maximum of 4 hours before applying a second coat,
additional coats after 4 hour cure could cause an adhesion problem.
Graffiti Stain Blocker cannot be used with TY•COTE Clear.
VII. QUANTITY AND COLORS
TY•COTE CLEAR & PIGMENTED Colors Available, TY•COTE Pigmented 1 Gallon, 5 Gallon, 30 Gallon Drums Available in TEX•COTE¨ Standard Colors or Special colors upon request.TEXCOTE¨ GRAFFITI GARD¨ IIIs FINISH
Two Component Kits, premeasured to be mixed on Job Site. 50/50 by Volume1 Gallon Kit - Use Gallon container to mix
Component A: 1/2 Full Gallon Container
Component B: 1/2 Full Gallon Container5 Gallon Kit - Use 5 Gallon container to mix
Component A: 1/2 Full 5 Gal. Container
Component B: 1/2 Full 5 Gal. ContainerGRAFFITI GARD¨ IIIs PASTE CLEANER
1 Gallon Metal Containers
A special blend of solvents designed to remove graffiti. Prolong the life of your building's surface and protect your investment with proper removal of graffiti. Use your cleaner as soon as possible after damage occurs.GRAFFITI STAIN BLOCKER
Available in white - 1 gallon containersVIII. AVAILABILITY AND COST
TEX•COTE¨ GRAFFITI GARD¨ IIIs Systems are available from TCA representatives in most cities throughout the United States, calling "Sweets Buy-line" (800/447-1982) or by contacting the manufacturer. For availability in foreign countries, please contact the manufacturer. Costs will vary from region to region. Contact your local representative.IX. GUARANTY/WARRANTY
Upon completion of coating in accordance with the Manufacturer's recommendations and Contract Documents, Textured Coatings of America, Inc., will extend its limited commercial warranty for product replacement when notification to Manufacturer is prior to the application of the coating and the application is in compliance with Manufacturer's recommendations for installation. Textured Coatings of America, Inc., shall have no obligation to contribute or otherwise participate in labor or costs associated with effecting repairs. Specimen copy is available upon request.X. MAINTENANCE
REMOVAL OF GRAFFITI - TEX•COTE¨ GRAFFITI GARD¨ IIIs PASTE CLEANER
- Using roller or brush, coat graffiti areas with TEXCOTE¨ GRAFFITI GARD¨ IIIs PASTE CLEANER
- Allow to stand three (3) and not longer than ten (10) minutes.
- Scrub with soft bristle brush. NOTE: Second application of cleaner may be needed.
- Rinse with water and scrub if necessary with soft bristle brush. Over rough surfaces, use high pressure water. Rinse well to prevent streaking.
NOTE:Early removal of Graffiti is easy. Prolonged exposure requires more effort to remove. Residue from run off when cleaning the walls from Graffiti should be collected and disposed according to local, State & Federal regulations.PRECAUTION:
Use protective clothes, glasses, gloves and mask.* Rinse immediately with water on contact. Volatile fumes are harmful if inhaled, use in well-ventilated areas. Avoid open flames.*Recommended respirator such as 1482-C102 (H.S.C. Corporation) or equal. Should comply with OSHA Regulations 29CFRI910134.
XI. TECHNICAL SERVICES
Technical services are available from the Manufacturer's facilities or sales representatives throughout the U.S.A. Textured Coatings of America, Inc.'s Technical Department will provide special specifications upon request.XII. FILING SYSTEMS
Sweets Architectural Filing System and/or SPECDATA II FILES. For additional literature, request from Manufacturer.
IIIS-1297