The Ultimate in Water Repellents
- High Performance Water Repellents
- Regular Clear Sealer
- Heavy Duty Clear Sealer
- Semi-transparent Stain
- Opaque Stain
- Siloxane Clear Sealer
- Silane Clear Sealer
| Suitable for a wide range of surfaces such as precast, architectural and poured concrete, brick, stucco, block, wood, limestone, aggregate panels and other surfaces.
Excellent long term water repellency, resistance to discoloration, efflorescence, water penetration, dirt and mildew accumulation. Available in V.O.C. compliant formulations in those states where mandated. |
||
Product Description
Series 100 Regular: A clear, penetrating water repellent sealer for internal and external protection. Series 100 contains PLAZTEX, a hydrocarbon plasticizer which is water white, non-gloss, stain and oxidation resistant.
May be used for concrete, cement plaster, painted surfaces, natural stone panels, brick, wood and other nonporous surfaces.
Solids content is 8% minimum of sealer material.
Series 200, Heavy Duty Clear: Heavy Duty is specially formulated for a more porous surface. Upon drying, the surface is enriched and slightly darkened with a low sheen.
Recommended over normal weight block systems, slump stone, split face block, cinder block, adobe block, lightweight concrete, and exposed aggregate systems. Two (2) coat water repellent system which requires a 24-hour curing period under ideal weather conditions prior to second coat application.
Solids content is 20% minimum of sealer material.
Series 400 Semi-transparent; and Series 500, Opaque Stains: A solvent based resin system which penetrates into the masonry surface for water repellency, aesthetic staining, greater depth of color and allows moisture vapor to escape from the surface.
Recommended for concrete systems, cement stucco, natural stone, architectural concrete, bush-hammered concrete, exposed aggregate systems, brick and normal weight concrete block.
Allow 24-hour curing between coats when roller applied. Solids content is 25% minimum of sealer material.
Series 600 and Series 1500 Siloxane Clear Sealers:
A one component penetrating sealer. This product reacts chemically with the substrate to form a repellency to salt and water while still allowing the substrate to remain permeable to water vapor.
Series 1500 meets NCHRP-244 Test Method Requirements for concrete deck sealers. Request more detailed technical data from manufacturer.
Solids content for Series 600 is 6% siloxane. For Series 1500, it is 15% siloxane.
Series 140 and Series 120 Silane Clear Sealers:
RAINSTOPPER¨ Silane is a chemical treatment which causes concrete, masonry, limestone or wood to become repellent to salt and water. It is available in two grades for concrete, masonry, limestone and one grade for wood.
RAINSTOPPER¨ Silane has an excellent performance record. Testing has proven that it is superior to oligomeric poly siloxanes, stearates, siliconates, silicates, urethanes, butadienes, chlorinated rubber, epoxies, and oils.
RAINSTOPPER¨ 140 - Our premium grade silane weatherproofing product contains 40% Alkyltrialkoxy Silane in Mineral Spirits. It is used to protect and maintain bridges, parking garages, airport pavements, industrial plants, buildings and other concrete and masonry structures in the most severe environments. RAINSTOPPER¨ 140 penetrates up to 1/2 inch with each application.
RAINSTOPPER¨ 120 -Our high grade silane water repellent product contains 20% Alkyltrialkoxy Silane in Mineral Spirits. It is used to protect and maintain bridges, buildings, parking garages, pavements, plants, and other brick and concrete structures in the most severe environments. RAINSTOPPER¨ 120 penetrates up to 1/4 inch with each application.
RAINSTOPPER¨ Siloxane and Silane Sealers protect and preserve the substrate without altering the surface texture or appearance. Substrates which can be treated include limestone aggregates, gravel, concrete, stone, wood, brick, masonry, flagstone, paper, sandstone, limestone, marble, stucco, precast concrete, architectural concrete and synthetic stone.
After being chemically treated, these substances become highly resistant to staining, spalling, weathering, efflorescence, water intrusion, salt intrusion, fungi and mildews, deterioration, freeze thaw scaling and reinforcing steel corrosion.
Coverage Rates
The following figures are estimated coverage rates and may vary according to the porosity of surface and surface conditions. Only complete and full saturation with the sealer material will satisfy the surface porosity of the substrate being treated.
Series 100, Regular: (one coat)
Surface Square Feet/Gallon Concrete Walls (above grade)..............100-125 Concrete floors/slab......................100-125 Brick......................................75-100 Cement stucco*.............................75-100 Aggregate panels..........................100-125 Limestone.................................100-125 Smooth surface wood.......................100-125 Shingles/shakes............................50- 75*Cement stucco color coats may bleed in the presence of solvent based materials.
Provide a test area patch utilizing the sealer material to determine cement stucco reaction to sealer application. Consult manufacturer for recommendations.
Series 200, Heavy Duty: (two coats)
Surface Square Feet/Gallon Normal weight concrete block*,.............100-125 each coat split face block, cinder block, slump stone, and adobe block.*contact the manufacturer for recommendations over light weight block.
Series 400 and 500: (two coats)
Surface Square Feet/Gallon Concrete walls.............................125-150 Precast concrete...........................175-200 Cement stucco..............................125-150 Brick......................................125-150 Normal weight concrete block...............1st coat: Series 200; ....................................100-125 ....................................2nd coat: 125-150Series 600 and 1500: (one coat)
Surface Square Feet/Gallon Concrete decks and walls...................100-125RAINSTOPPER¨ 1500 Siloxane-Sealer meets and/or exceeds NCHRP-244 Test Method for horizontal concrete.
RAINSTOPPER¨ 140 and RAINSTOPPER¨ 120 Silane Sealers meet and or exceeds NCHRP-244 Test Method for horizontal concrete.Technical Data
Series 100/200
Water Repellency...........................Excellent* Resistance to Discoloration................Excellent* Water Erosion..............................Excellent* Weatherometer..............................Excellent* Series 100, Flash point:...................115¡F Series 200, Flash point:...................54¡FThese materials are combustible in liquid form
Keep away from children.Series 100
Fed. Spec. SSW-110C........................PassesSeries 100/200/400 Additional Performance Data
Efflorescence Testing......................Excellent Resistance (ASTM C67) (Series 100/400) Salt Spray Testing.........................No Effect After 3000 Hours (ASTM B117) Resistance to Water........................No Appreciable Change Absorption after 2500 Hours Exposure Field Testing..............................10 Years*Standard test basis available from manufacturer's spec data sheet.
Series 600/1500 Siloxanes Test Results
Properties/Test RS 600 RS 1500* Solvent Mineral Spirits Mineral Spirits Color Clear Clear Flash Point 96.8¡F 96.8¡F Test Application Rate 125 sf/gallon 125 sf/gallon (Standard per Test Method) NCHRP 244 Report Series 1 Test RS 600 RS 1500* % Reduction in Water Absorption 82.3 85.1 % Water Vapor Transmission 111.9 119.9 % Reduction in Chloride Intrusion NCHRP 244 84.8 92.1 Freeze-Thaw Scaling Resistance ASTMC-672(50 cycles) Minimum Scaling No Scaling Freeze-Thaw Durability ASTM C-666 98.0 96.2 Series IV Test Chloride Screening 97.6 Southern Climate Exposure (% More Effective) Florida D.O.T. Test Method PASSES*RAINSTOPPER¨ 1500 meets and/or exceeds all NCHRP-144 Test Method and the Florida Department of Transportation requirements for a Type "O" High Performance Penetrating Sealer. All test results relative to untreated control samples.
NOTE: RAINSTOPPER¨ 600 and RAINSTOPPER¨ 1500 is available to comply with VOC requirements for California, as well as other states where mandated.
Series 140/120 Silanes
SALT RESISTANCE (AASHTO T259, T260)
Sample % Chloride Product Depth Inch Ion by Wt. Control Uncoated 1/16"-1/2" 0.0792 Control Uncoated 1/2"-1" 0.0581 RAINSTOPPER¨ 120 1/16"-1/2" 0.0269 RAINSTOPPER¨ 120 1/2"-1" 0.0032 RAINSTOPPER¨ 140 1/16"-1/2" 0.0144 RAINSTOPPER¨ 140 1/2"-1" 0.0030SALT WATER WEIGHT GAIN WJE Assoc.
NCHRP Report No. 244: Test 21 DaysAverage Average Reduction Product Wt. Gain % in Wt. Gain % RAINSTOPPER¨ 120 0.42 80 RAINSTOPPER¨ 140 0.37 83CHLORIDE ION CONTENT WJE ASSOC.
NCHRP Report No. 244; Test 21 DaysChloride Ion Reduction of % By Wt. of Chloride Ion Content Product Concrete In Concrete % RAINSTOPPER¨ 120 0.039 82 RAINSTOPPER¨ 140 0.024 89 Uncoated Concrete 0.215SCALING RESISTANCE ASTM C-672-84
50 Cycles RAINSTOPPER¨ 120 No Scaling RAINSTOPPER¨ 140 No ScalingNCHRP REPORT NO. 244
Series Iv, Southern ExposureReduction in Chloride Ion Content RAINSTOPPER¨ 120 100% RAINSTOPPER¨ 140 100%WATER VAPOR TRANSMISSION
ASTM E96 Procedure BAverage Vapor Average Transmission Permeance Product (Grains/Hr/Sq. Ft.) (Perms) control 1.32 3.25 RAINSTOPPER¨ 120 0.9 2.23 RAINSTOPPER¨ 140 0.74 1.83ALL TEST RESULTS PRODUCED USING RAINSTOPPER¨ 120 & 140
Note: RAINSTOPPER¨ 120 and RAINSTOPPER¨ 140 may be manufactured to comply with VOC requirements in California and other states where mandated. All test results based on a coverage rate of 12 S.F. per gallon standard NCHRP 244 Test Method.
Installation
Application Equipment:
Series 100, Regular: Airless spray, low pressure (20-25 pounds per square inch) for maximum penetration, or Hudson sprayer. Suitable for application with roller or brush.Series 200, Heavy Duty; Series 400, Semi-transparent; Series 500, Opaque: Commercial grade, airless spray unit. Suitable for application with roller or brush. Avoid excess material application and runs.
Surface Preparation:
All surfaces must be sound, clean, dry and cured a minimum of 28 days prior to the application of the sealer or masonry stain.Surface contaminants such as dust, dirt, mildew, form oils, curing agents and loose substrate materials should be thoroughly removed. Painted surface exhibiting loose, flaking, or oxidized paint surfaces must be thoroughly removed by sandblasting, waterblasting, electric sanding, or wire brushing as required by the manufacturer.
Large cracks, holes, or voids must be filled with cement patching compound such as Tax-Bond cement adhesive system. Patching compound finish texture to match existing adjacent finish surfaces. Cracks over one-sixteenth (1/16) of an inch and less than one-eighth (1/8) of an inch should be filled with Flex-Patch patching compound. Interfacing of wail joints should be sealed with a polysulfide type sealant.
Application of Sealer:
Series 100, Regular:
Begin application at top of the surface area requiring sealer and use vertical strokes to break the surface tension and initiate capillary action. Follow immediately with slow horizontal strokes with additional material in order to "flood" the surface. Manufacturer recommends that an eight (8) to twelve (12) inch "rundown" be maintained in order to obtain maximum sealer protection. Substrate porosity of the material may require more than one application in order to satisfy the necessary absorption characteristics of the material surface. Series 200, Heavy Duty: Begin application with a commercial grade airless sprayer, roller or brush. Avoid "rundowns" and sags. Provide a 24-hour cure between coats under ideal weather conditions.Series 400 and 500 (Except Block Substrates):
Stir material well before applying to any substrate. When spraying, apply initial coat of stain as heavy as possible without excess sags or "rundowns." Immediately go back over the surface with the second (fog) coat so that entire surface is uniformly wet, which will minimize lap marks. When spraying large areas, use single direction passes, feathering out to reduce overlap marks. Establish a breakline conforming to the surface design breaks where possible. The first coat should not dry prior to the second coat application when spraying. Roller applied should cure 24 hours between first and second coat application.Series 400 and 500 (Block Substrates Only):
All block surfaces require a first coat of Series 200, Heavy Duty sealer according to the recommended coverage rate requirements. Avoid all sags or "rundowns." Allow 24 hours, minimum, cure time under ideal weather conditions before applying Series 400 and Series 500.Application-Series 140/120 & 1500/600:
RAINSTOPPER¨ Silane & Siloxane Sealer are ready to use and shall be applied as supplied. It cannot be diluted or altered in any way. DO NOT allow any water to get into the solution. Application equipment should contain NO WATER. If the equipment to be used has been cleaned using water, it may still be wet. It should be flushed with a small amount of Anhydrous Alcohol or RAINSTOPPER¨ Sealer prior to beginning the actual application.The RAINSTOPPER¨ Sealers may be applied by brush, roller or spray. The most effective method for applying the RAINSTOPPER¨ Sealers is to spray it on the surface using low pressure (15 p.s.i.) positive displacement airless spray equipment. All spray equipment should be fitted with fan spray nozzles and then spray adjusted to a "Wet Spray" condition. Mist spraying can allow a substantial portion of the material to be lost to the atmosphere and slow down the rate of application. Deck areas should be sprayed using a spray-bar type unit and other areas sprayed with hand spray units. The spray equipment, tank, hoses, etc., should be thoroughly clean, free of water, foreign matter and oil residue prior to use for spraying the RAINSTOPPER¨ Sealers. The coverage rate shall be as per the NCHRP 244 Test Method or as designated by the governing highway department or engineer of record. Horizontal surfaces will be completely flooded; vertical surfaces will have spray patterns that will run 6 to 8 inches before soaking in when application rates are correct.
If the applicator is unable to complete the entire application at one time, the place where the application was stopped shall be clearly marked. Partially used containers should be properly sealed and protected from contamination by water or other foreign substances.
Provide adequate ventilation during and after application, such that RAINSTOPPER¨ odors are not evident. Product is flammable. Use reasonable care and caution. Do not proceed when excessive winds (fifteen (15) m.p.h, or over) could interfere with application. Concrete shall have cured to design strength prior to application of the RAINSTOPPER¨ Sealers.
All surfaces must be able to absorb the RAINSTOPPER¨ Sealers. The Silane can be fully effective only when the solution is able to penetrate into the concrete or masonry pores and capillaries.
To determine the surface absorption characteristics, observe the rate at which a small drop of the RAINSTOPPER¨ Sealer penetrates into the substrate. It will begin to penetrate immediately and be absorbed by the surface within a few seconds if the surface is sufficiently clean to allow penetration. If the surface retains an "oil spot" appearance, it must be cleaned.
Surfaces which are not clean (i.e., surfaces where the pores and capillaries may be clogged with oils, dirt, dust, curling compound and/or other coatings, etc.) must be cleaned sufficiently to allow enough pores to be opened so that the RAINSTOPPER¨ Sealers can penetrate as described above. Clean Up
Clean up wet overspray on glass, metal, or painted surfaces immediately while wet, with either mineral spirits, xylol, or toluene. Dry RAINSTOPPER¨ adheres tightly to surfaces.
Key Features, and Advantages
Excellent resistance to water erosion, moisture intrusion, efflorescence, mildew and dirt build-up. Minimizes spalling and cracking of concrete, extends life of painted surfaces, reduces capillary action. Exceptional substrate penetration while still allowing the substrate to breathe. Greater water repellency and ultraviolet resistance properties when compared to other major brands. Availability and Cost
RAINSTOPPER¨ is available in most states, by calling "Sweets Buy Line" or by contacting the manufacturer. Costs may vary from region to region. Contact your local representative.
Quantities and Colors
Container Size: 5 gallon pails; 30 and 55 gallon drums.
Colors: clear, Series 400 and 500 are available in 16 Standard TCA
Colors. Special colors on request.Warranty
Upon completion of application of coating in accordance with the manufacturer's recommendations, Textured Coatings of America, Inc. will extend its limited commercial warranty for product replacement as a result of defect in the material. The manufacturer must be notified prior to the application of the coating and the application must be in compliance with the manufacturer's recommendations for installation. Textured Coatings of America, Inc., shall have no obligation to or otherwise participate in labor or cost associated with effecting repairs. Specimen copy of material warranty available upon request.
Maintenance
No particular maintenance is required. However, should any of the product become soiled, simply clean with light water pressure and mild detergent.
Technical Services
Technical services are available from the manufacturer's facilities or sales representatives throughout the U.S.A. Textured Coatings of America Research and Development Department will provide specifications upon request.
Analysis of particular project requirements and recommendations for the proper use of RAINSTOPPER¨ Siloxane & Silane Sealers are available upon request.
Filing Systems
SPEC-DATA¨ II
Sweets Architectural Filing System 09800/TEX
Additional product information available upon request.See Our Other Catalogs
09800/TEX: TEXCOTE¨ Decorative Protective Coating Systems
RSB-1297